logo
Good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Plastic Testing Equipment
Created with Pixso. Color Assessment Cabinet For Plastic Test

Color Assessment Cabinet For Plastic Test

Brand Name: GC
Model Number: GC-WAW-2000D
MOQ: 1 Set
Price: Negotiated
Delivery Time: In stock
Payment Terms: TT
Detail Information
Place of Origin:
China
Certification:
ISO
Name:
Color Assessment Cabinet
Model:
GC-WAW-2000D
Light Source:
UV Ultraviolet Light Source
Transport Package:
Wooden Package
Packaging Details:
Wooden package
Supply Ability:
100 Sets
Product Description

Color Assessment Cabinet

 

Product description:

 

Standard light source colorimetric light box is widely used in textile, plastic, paint, ink, printing, dyeing, printing, pigment, packaging, ceramics, leather, cosmetics and other industries in the field of color management, used to accurately calibrate the color deviation of goods, improve product quality and market competitiveness. It is especially important to use the standard light source to detect the color deviation of goods on cloudy days and dark nights.

 

Technical parameters:

 

D65 The use of artificial fluorescent lamps D65 approved by the International Commission on Illumination (CIE) as the basic lighting source, D65 light source in addition to being used as a contrasting color, but also defined by most of the world's societies or groups as a gray-scale contrast when the lighting source.

 

UV Ultraviolet light source (Ultra:Violet llluminant) .Due to the widespread use of fluorescent and whitening dyes in industrial production, the best way to detect this effect is to use a UV light source, because UV light in the irradiation of fluorescent dyed substances will produce obvious changes in brightness, so that the naked eye can be easily detected.

 

Family Light Source (Filament Lighting) is suitable for color management instead of observing colors under a light source in a home or hotel room, such as underwear, bedding, and other products.

 

CWF / TL84 / Some customers require the use of this light source for color matching, such as the United States customers often require the use of Cool White Fluorescent (CWF) light source, European and Japanese customers will require the use of Triphosphor Lamp P15 (TL84) light source. Illumination of light sources in the range of 750 to 3200 luxes.

 

When performing color matching work, the background color and lightness are very important. Since color is a subjective perception, comparing colors against different backgrounds will produce different results. Therefore, all background colors are specified as Neutral Grey, which must be less than one-third the reflectivity of the incident light. Separate records of the use of each type of light source, (it is recommended that the use of 2,000 hours after the replacement of the light tube), to avoid the detection error caused by the aging of the light tube. 

 

Introduction of Guangdong Guangce Instrument Technology Co.,Ltd

Color Assessment Cabinet For Plastic Test 0公司信息1.jpg

公司信息2.jpg

广测详情页里的公司介绍英文版_03.jpg

 

Color Assessment Cabinet For Plastic Test 4

Color Assessment Cabinet For Plastic Test 5

 

 

 

 

Good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Plastic Testing Equipment
Created with Pixso. Color Assessment Cabinet For Plastic Test

Color Assessment Cabinet For Plastic Test

Brand Name: GC
Model Number: GC-WAW-2000D
MOQ: 1 Set
Price: Negotiated
Packaging Details: Wooden package
Payment Terms: TT
Detail Information
Place of Origin:
China
Brand Name:
GC
Certification:
ISO
Model Number:
GC-WAW-2000D
Name:
Color Assessment Cabinet
Model:
GC-WAW-2000D
Light Source:
UV Ultraviolet Light Source
Transport Package:
Wooden Package
Minimum Order Quantity:
1 Set
Price:
Negotiated
Packaging Details:
Wooden package
Delivery Time:
In stock
Payment Terms:
TT
Supply Ability:
100 Sets
Product Description

Color Assessment Cabinet

 

Product description:

 

Standard light source colorimetric light box is widely used in textile, plastic, paint, ink, printing, dyeing, printing, pigment, packaging, ceramics, leather, cosmetics and other industries in the field of color management, used to accurately calibrate the color deviation of goods, improve product quality and market competitiveness. It is especially important to use the standard light source to detect the color deviation of goods on cloudy days and dark nights.

 

Technical parameters:

 

D65 The use of artificial fluorescent lamps D65 approved by the International Commission on Illumination (CIE) as the basic lighting source, D65 light source in addition to being used as a contrasting color, but also defined by most of the world's societies or groups as a gray-scale contrast when the lighting source.

 

UV Ultraviolet light source (Ultra:Violet llluminant) .Due to the widespread use of fluorescent and whitening dyes in industrial production, the best way to detect this effect is to use a UV light source, because UV light in the irradiation of fluorescent dyed substances will produce obvious changes in brightness, so that the naked eye can be easily detected.

 

Family Light Source (Filament Lighting) is suitable for color management instead of observing colors under a light source in a home or hotel room, such as underwear, bedding, and other products.

 

CWF / TL84 / Some customers require the use of this light source for color matching, such as the United States customers often require the use of Cool White Fluorescent (CWF) light source, European and Japanese customers will require the use of Triphosphor Lamp P15 (TL84) light source. Illumination of light sources in the range of 750 to 3200 luxes.

 

When performing color matching work, the background color and lightness are very important. Since color is a subjective perception, comparing colors against different backgrounds will produce different results. Therefore, all background colors are specified as Neutral Grey, which must be less than one-third the reflectivity of the incident light. Separate records of the use of each type of light source, (it is recommended that the use of 2,000 hours after the replacement of the light tube), to avoid the detection error caused by the aging of the light tube. 

 